condor d.c. power supplies, inc., a subsidiary of sl industries, inc. 805-486-4565 ?(800) 235-5929 fax: (805) 487-8911 http://www.condorpower.com model pwr output #1 output #2 output #3 output #4 PBO-200 200 w 4.75 v to 5.25 v 11.5 v to 25.2 v 9.5 v to 15.8 v 4.75 v to 12.6 v (cont.) @ @ @ @ 240 w 3.0 a to 30.0 a 0.4 to 4.0 a 0.4 to 5.0 a 0.3 a to 3.0 a (peak) 6.0 a (peak) 6.0 a (peak) 200 watts power factor corrected wide range adjustable multiple outputs the pbo 200 series of high-reliability, ac input power supplies are designed for computer, networking, telecommuni- cation and industrial equipment applica- tions. these models feature a universal power factor corrected input plus inde- pendently isolated and regulated out- puts. the auxiliary outputs are adjustable over a wide range (up to 2.6 to 1). this wide range of adjustability provides greater flexibility, especially in meeting non-standard output voltage require- ments. outputs may be connected in either polarity or stacked in series as needed. outputs 2 and 3 accommo- date up to 50% greater peak currents for applications with surge require- ments. the optional cover with fan pro- vides a low-profile cooling solution that increases the overall height by only 0.25? standard pbo series option cf PBO-200 featuring: 200 w continuous ?240 w peak power universal input for 115 v or 230 v, 47-65 hz, single phase ac four independently isolated and regulated outputs wide range of adjustable auxiliary outputs (up to 2.6:1) up to 50% greater peak currents on two outputs typical power factor ?0.99 low ripple and noise on all outputs typical 70% efficiency dc power good signal remote on/off and remote sense features low profile fan/cover option
condor d.c. power supplies, inc., a subsidiary of sl industries, inc. 805-486-4565 ?(800) 235-5929 fax: (805) 487-8911 http://www.condorpower.com function 115 vac 230 vac connector tb1- line line 1 tb1- neutral line 2 tb1- safety ground safety ground ac input (90-264 vac continuous range) function location notes connector output #1 tb2-1 4.75v to 5.25v tb2-2 rtn (isolated) output #2 tb3-1 11.5v to 25.2v tb3-2 rtn (isolated) output #3 tb3-3 9.5v to 15.8v tb3-4 rtn (isolated) output #4 tb3-5 4.75v to 12.6v tb3-6 rtn (isolated) dc output barrier strip #6-32 screws 0.325 inch centers bus bars # 8 - 32 screws barrier strip #6-32 screws 0.375 inch centers function location status connector enable j1-1 enable j1-2 output #1 rtn dc power good j1-4 dc power good j1-3 output #1 rtn remote sense j2-2 output #1 sense + j2-1 output #1 sense - status and control molex part # 22 - 23 - 2041 mates with molex part # 22 - 01 - 3047 specifications: all models input ac input: 85-264 v ac continuous range, 47 to 65 hz. internally fused at 6.3 a. power factor: 0.99 typical at full load. meets en61000-3-2. inrush: cold start ac current is less than 35 a at 115 vac and 70 a at 230 vac. limited by a thermistor. brownout protection: holds regulation to 85 vac. holdup time: 20 ms after removal of power at nominal line and full load. efficiency: 75% typical. ac power fail: provides ttl ?? 6 ms before output voltage goes out of regulation band upon loss of ac power. also provides a ttl level ??for 100 ms (minimum) at starting. output adjustability: output #1 is adjustable ?%. output #3 and 4 are wide range adjustable, (see table). line & load reg: ?.6% on all outputs over ac input range and loads within the ranges specified in the table. ripple & noise: less than 1% p-p or 100 mv, whichever is greater. remote sense (output #1) : compensates for 250 mv total line drop. open sense lead protection. temperature coefficient: to be determined. stability: 0.1% over 8 hours after 30 minutes warm-up. transient response: output voltage returns to within 1% in less than 500 ? for a 25% load change. peak transient does not exceed 3%. overload protection: all outputs are protected against overload and input cycling off/on is required to reset latched-off protection mode. overvoltage protection (output #1) : protects load against power supply induced overvoltage. trip point is factory set so that output voltage cannot exceed 6.5 v. peak output current: (outputs #2 and 3) dual current ratings define continuous and peak currents. the peak current shown can be delivered for a maximum period of 15 seconds. remote inhibit: contact closure to the negative sense line or a ttl level ??turns off dc outputs. dc power good: provides a ttl ??open collector when output #1 is above 4.6 v nominal. redundancy: external or-ing diodes and forced current sharing on output #1 provide ?+1? capability. remote sense (+s) compensates for additional 0.6 v diode voltage drop. when the current sharing terminal is connected between units, current sharing remains within 10% of the unit s full output current rating. reverse voltage: protected against reverse voltage up to supply current rating. cooling: 30 cfm required to achieve full ratings. enable: contact closure in the negative output #1 terminal or a ttl level ?? turns off dc outputs. 200 watts 9 x 5 x 2 PBO-200 (l) (n) ( ) dimensions: inches millimeters environmental thermal protection: shuts down power supply if overheated. automatic recovery. temperature range: 0 to 40? at full ratings.output power linearly derated to 50% at 70?. safety agencies: ul1950; csa 22.2 #950; vde 0805 / en 60950 ce markings to low voltage directive ?all pending. conducted rfi: meets fcc part 151 class b. en 55022/b. output isolation: isolated from ground 50 vdc. cooling: 30 cfm required to achieve full ratings. options: option cf: available with enclosed cover and fan. consult factory for other available options. PBO-200 2.7 lbs - 1.4 kgs molex part # 22 - 23 - 2021 mates with molex part # 22 - 01 - 3027
|